GCK Three-Phase Low Voltage Switchgear – 2500A Main Busbar

This gck three-phase low voltage switchgear – 2500a main busbar is intended for low-voltage power distribution, feeder management, and plant-side electrical control in commercial and industrial facilities. It supports practical outgoing feeder configuration, protective coordination, and optional communication functions for project-driven LV distribution systems.

Technical Parameters & Ratings

IEC / ANSI CertifiedFactory Standard
Rated Voltage400 V / 415 V / 440 V
Rated Current2500 A
Frequency50 Hz / 60 Hz
PhaseThree Phase
Structure TypeWithdrawable low-voltage switchgear
Insulation TypeAir insulated
StandardIEC / GB / customized project specification
InstallationIndoor / outdoor according to enclosure design
ApplicationDistribution substations / industrial plants / building electrical systems

Technical Highlights

  • This product combines structured cabinet design, practical electrical coordination, and project-specific configuration flexibility. It is suitable for power systems that need reliable switching or control performance, organized maintenance access, and scalable options for monitoring, communication, and protection.

Application Scenarios

  • Main low-voltage distribution rooms
  • Commercial buildings and infrastructure projects
  • Industrial plants and process facilities
  • Emergency and standby power systems
  • Data center and utility support applications

Key Features

  • Designed for low-voltage power distribution, feeder control, and plant-side electrical coordination
  • Available in withdrawable, fixed type, or modular cabinet architecture according to model
  • Supports project-based busbar ratings, outgoing feeders, and protective device selection
  • Optional metering, communication, and monitoring functions available for smart distribution projects
  • Suitable for commercial buildings, industry, infrastructure, and utility support systems
  • Structured panel design for practical maintenance and long-term service

Optional Configurations

  • Rated current and outgoing feeder layout
  • Breaker brand, control logic, and metering options
  • Communication and monitoring functions
  • Cabinet protection level and enclosure finish
  • Busbar material and cable entry arrangement
  • Labeling, mimic diagram, and project-specific wiring documents
  • Color, nameplate language, and document package
  • Ambient temperature, altitude, and installation condition adaptation

Frequently Asked Questions

What is the GCK low-voltage switchgear used for?

It handles low-voltage power distribution and feeder control in substations, industrial plants and infrastructure projects where a high main busbar rating is required.

What is the main busbar rating?

The main busbar is rated 2500 A, with incoming and feeder circuit ratings configured to the project single-line diagram.

Is the withdrawable design easy to maintain?

Yes. Modules can be racked out for inspection or replacement without de-energizing the main busbar, keeping critical feeders in service during maintenance.

Which standards does the switchgear comply with?

The panels are designed and assembled to IEC 61439-1 and IEC 61439-2, with GB 7251 and project-specific specifications accommodated on request.

Can the switchgear be customized for my project?

Yes. Busbar rating, feeder layout, breaker brand, metering and protection functions, communication options, enclosure protection level and finish are all configurable.

Scroll to Top