Technical Parameters & Ratings
| Rated Capacity | 5000 kVA |
|---|---|
| Primary Voltage (U1) | 33,000 V (33 kV) |
| Secondary Voltage (U2) | 415 V / 240 V (3-Phase 4-Wire) |
| Vector Group | Dyn11 |
| Rated Frequency | 50 Hz |
| Cooling Method | ONAN (Oil Natural Air Natural) |
| Primary Current (I1) | 87.48 A |
| Secondary Current (I2) | 6956.1 A |
| Guaranteed No-Load Loss (P0) | 4100 W |
| Guaranteed Load Loss (Pk at 75°C) | 31000 W |
| Short-Circuit Impedance (Uk) | 5.5% |
| HV Insulation Level | LI 170 / AC 70 (33kV Class) |
| Temperature Rise Limits | Top Oil ≤ 50K, Winding ≤ 55K (45°C Ambient) |
| Creepage Distance | ≥ 31 mm/kV (Outdoor Tropicalized Porcelain) |
| Core & Coil Weight | 6800 kg |
| Insulating Oil Weight | 3900 kg |
| Total Assembled Weight | 13800 kg |
| Overall Footprint (L×W×H) | 2750 mm × 1750 mm × 2800 mm |
| Governing Standards | IEC 60076, BS 171, SON NIS, NERC Code |
Technical Highlights
- This product combines dependable transformer platform design, flexible project configuration, and practical export-oriented construction. It is suitable for applications requiring stable electrical performance, configurable voltage ratios, outdoor durability, and documentation support for international project supply.
Application Scenarios
- Solar power plants
- Wind farm collector and grid interface systems
- Photovoltaic station and inverter interconnection projects
- Battery energy storage systems (BESS)
- Renewable energy substations and export EPC projects
Key Features
- 5000 kVA rated capacity for renewable interconnection, step-up, or project-side power conversion
- Designed for solar, wind, PV, or energy-storage power system applications
- Configurable voltage ratio for inverter-side, collector-side, or grid-side connection
- Oil-immersed construction for dependable cooling in outdoor renewable projects
- Project-oriented accessory and monitoring options available
- Suitable for IEC-based renewable projects and export EPC supply
Optional Configurations
- Low-voltage side rating and voltage ratio
- Frequency: 50 Hz or 60 Hz
- Vector group and tapping range
- Copper or aluminum winding
- Cooling method, accessory package, and monitoring option
- Tank structure, coating system, and special environmental adaptation
- Color, nameplate language, and document package
- Ambient temperature, altitude, and installation condition adaptation
Frequently Asked Questions
What is the typical lead time for a 5000 kVA power transformer?
Standard lead time is 30 days after drawing approval. Large power transformers are built to order; the final schedule is confirmed once your technical specification and test scope are frozen.
Which standards does this transformer comply with?
The unit is designed and manufactured to IEC 60076 (ANSI/IEEE C57 where required), with routine tests performed on every unit before shipment.
Can the vector group and tap range be customized?
Yes. Vector group, tap range, impedance and cooling class (ONAN/ONAF/OFWF) are all configurable to match your grid study and protection scheme.
What test reports are supplied with the transformer?
Every unit ships with routine test reports covering ratio, winding resistance, insulation resistance, power-frequency withstand, induced voltage and loss measurements as applicable.
Do you support installation and commissioning for export projects?
Yes. Supervision of installation and commissioning can be arranged for EPC and utility projects, together with a full document package in your required language.