Technical Parameters & Ratings
| Rated Capacity | 10000 kVA |
|---|---|
| High Voltage | 35 kV |
| Low Voltage | 0.4 kV / 0.415 kV / 0.433 kV / customized |
| Frequency | 50 Hz / 60 Hz |
| Phase | Three Phase |
| Cooling Method | ONAN / ONAF optional |
| Vector Group | YNd11 / Dyn11 / Yyn0 / customized |
| Tap Changer | Off-circuit tap changer / on-load tap changer optional |
| Tapping Range | ±2 x 2.5% / ±5% / customized |
| Winding Material | Copper / Aluminum |
| Core Material | CRGO silicon steel |
| Insulation Medium | Mineral insulating oil |
| Application Type | Solar / wind / BESS / renewable grid integration |
| Tank Type | Conservator tank / sealed tank optional |
| Impedance Voltage | According to standard / customized |
| No-Load Loss | According to standard / customized |
| Load Loss | According to standard / customized |
| Standard | IEC / customized project specification |
| Installation | Outdoor |
| Application | Solar farms / wind projects / PV stations / BESS systems / renewable substations |
Technical Highlights
- This product combines dependable transformer platform design, flexible project configuration, and practical export-oriented construction. It is suitable for applications requiring stable electrical performance, configurable voltage ratios, outdoor durability, and documentation support for international project supply.
Application Scenarios
- Solar power plants
- Wind farm collector and grid interface systems
- Photovoltaic station and inverter interconnection projects
- Battery energy storage systems (BESS)
- Renewable energy substations and export EPC projects
Key Features
- 10000 kVA rated capacity for renewable interconnection, step-up, or project-side power conversion
- Designed for solar, wind, PV, or energy-storage power system applications
- Configurable voltage ratio for inverter-side, collector-side, or grid-side connection
- Oil-immersed construction for dependable cooling in outdoor renewable projects
- Project-oriented accessory and monitoring options available
- Suitable for IEC-based renewable projects and export EPC supply
Optional Configurations
- Low-voltage side rating and voltage ratio
- Frequency: 50 Hz or 60 Hz
- Vector group and tapping range
- Copper or aluminum winding
- Cooling method, accessory package, and monitoring option
- Tank structure, coating system, and special environmental adaptation
- Color, nameplate language, and document package
- Ambient temperature, altitude, and installation condition adaptation
Frequently Asked Questions
What is the role of the step-up transformer in a wind farm?
It raises the turbine or collector system voltage to the grid interconnection level, allowing power to be transmitted with acceptable losses.
How is the transformer adapted to fluctuating wind output?
Loading profile, thermal design and cooling are engineered for the cyclic loading typical of wind generation, and tap range can be set for collector voltage variation.
Is a special design required for offshore or coastal sites?
For coastal and offshore applications, enhanced corrosion protection and enclosure ratings are specified according to the site environment.
What voltage ratios are typically supplied?
Common collector-to-grid ratios follow the project design; the exact ratio and impedance are engineered to your grid study.
Are routine tests performed on every unit?
Yes. Every unit undergoes routine testing before shipment, with test reports issued for the project file.