1000 kVA 34.5kV 60Hz ANSI Three-Phase Oil-Immersed Transformer

,

1000 kVA 34.5kV 60Hz ANSI Three-Phase Oil-Immersed Transformer

This 1000 kVA 60 Hz oil-immersed transformer is configured for ANSI and Latin American grid standards. Suitable for utility distribution, industrial, and infrastructure projects operating at 60 Hz. Designed to ANSI/IEEE C57.12 guidelines with IEC 60076 cross-reference. Export-ready from Hefei, China.

Technical Parameters & Ratings

IEC / ANSI CertifiedFactory Standard
Rated Capacity1000 kVA
Primary Voltage (U1)11,000 V (11 kV)
Secondary Voltage (U2)415 V / 240 V (3-Phase 4-Wire)
Vector GroupDyn11
Rated Frequency50 Hz
Cooling MethodONAN (Oil Natural Air Natural)
Primary Current (I1)17.49 A
Secondary Current (I2)1391.2 A
Guaranteed No-Load Loss (P0)1150 W
Guaranteed Load Loss (Pk at 75°C)8100 W
Short-Circuit Impedance (Uk)4.5%
HV Insulation LevelLI 75 / AC 35 (11kV Class)
Temperature Rise LimitsTop Oil ≤ 50K, Winding ≤ 55K (45°C Ambient)
Creepage Distance≥ 31 mm/kV (Outdoor Tropicalized Porcelain)
Core & Coil Weight1650 kg
Insulating Oil Weight920 kg
Total Assembled Weight3200 kg
Overall Footprint (L×W×H)1650 mm × 1050 mm × 1750 mm
Governing StandardsIEC 60076, BS 171, SON NIS, NERC Code

Application Scenarios

  • Latin American utility distribution and rural electrification projects
  • Industrial facilities operating on 60 Hz ANSI power systems
  • EPC contractor packages for Americas and Caribbean infrastructure
  • Renewable energy grid connection in 60 Hz markets

Key Features

  • 1000 kVA rated capacity configured for 60 Hz ANSI and Latin American grids
  • high voltage class matching standard ANSI distribution voltages
  • Designed to ANSI/IEEE C57.12 guidelines with IEC 60076 cross-reference capability
  • 60 Hz frequency rating for Americas, Caribbean, and parts of Southeast Asia
  • Copper or aluminum winding available; pad-mount and substation configurations supported

Frequently Asked Questions

What does ANSI compliance mean for an oil-immersed transformer?

It means the transformer is designed and tested to the ANSI/IEEE C57 series standards, matching the 60 Hz, North American style requirements of the destination market.

Is this transformer suitable for 60 Hz systems?

Yes. The unit is engineered for 60 Hz operation with core flux, impedance and cooling matched to the 60 Hz design.

What accessories are typically supplied?

Typical accessories include bushings, pressure relief device, liquid level gauge, temperature indicator and tap changer, with the package agreed at order stage.

Which testing is performed before shipment?

Routine tests to the applicable ANSI/IEEE requirements are completed on every unit, with test reports provided.

Can the transformer be supplied with a specific bushing or accessory brand?

Accessory brands can be specified where required; the final selection is confirmed at order stage and stated on the nameplate documents.

Scroll to Top