100 kVA 33kV Three-Phase Oil-Immersed Distribution Transformer

,

100 kVA 33kV Three-Phase Oil-Immersed Distribution Transformer

This 100 kVA oil-immersed distribution transformer is designed for reliable power distribution in rural utility networks, industrial feeders, and infrastructure projects across Africa, MENA, and other grid markets. ONAN cooling with IEC 60076 design reference. Export-ready from Baoding, China.

Technical Parameters & Ratings

IEC / ANSI CertifiedFactory Standard
Rated Capacity100 kVA
Primary Voltage (U1)33,000 V (33 kV)
Secondary Voltage (U2)415 V / 240 V (3-Phase 4-Wire)
Vector GroupDyn11
Rated Frequency50 Hz
Cooling MethodONAN (Oil Natural Air Natural)
Primary Current (I1)1.75 A
Secondary Current (I2)139.1 A
Guaranteed No-Load Loss (P0)200 W
Guaranteed Load Loss (Pk at 75°C)1360 W
Short-Circuit Impedance (Uk)4.0%
HV Insulation LevelLI 170 / AC 70 (33kV Class)
Temperature Rise LimitsTop Oil ≤ 50K, Winding ≤ 55K (45°C Ambient)
Creepage Distance≥ 31 mm/kV (Outdoor Tropicalized Porcelain)
Core & Coil Weight310 kg
Insulating Oil Weight210 kg
Total Assembled Weight620 kg
Overall Footprint (L×W×H)1050 mm × 720 mm × 1250 mm
Governing StandardsIEC 60076, BS 171, SON NIS, NERC Code

Application Scenarios

  • Rural utility distribution network feeders
  • Industrial and mining site power supply
  • Infrastructure and EPC contractor projects in Africa and MENA
  • Renewable energy grid connection at voltage class

Key Features

  • 100 kVA rated capacity for rural utility and distribution network applications
  • class design suited for Africa, MENA, and IEC-standard grid markets
  • Oil-immersed ONAN structure for stable thermal performance in outdoor environments
  • Copper or aluminum winding options available to suit project budget requirements
  • Off-circuit tap changer with +/-2 x 2.5% or +/-5% range as standard

Frequently Asked Questions

What is an oil-immersed distribution transformer used for?

It steps down the network voltage to the level required by end users in utility, industrial and commercial distribution networks.

Which voltage classes does this range cover?

The range covers common distribution voltage classes with ratings sized to the load requirement of your network or project.

What cooling and insulation system is used?

The unit uses oil-immersed cooling with sealed or conservator tank design according to rating and site conditions, providing stable thermal performance.

Can the transformer be customized for my grid?

Yes. Voltage ratio, vector group, impedance, tap range and accessory package are all configurable to your specification.

Are routine tests performed before shipment?

Yes. Every unit is routine-tested before shipment and supplied with test reports for the project file.