Technical Parameters & Ratings
| Rated Capacity | 100 kVA |
|---|---|
| Primary Voltage (U1) | 11,000 V (11 kV) |
| Secondary Voltage (U2) | 415 V / 240 V (3-Phase 4-Wire) |
| Vector Group | Dyn11 |
| Rated Frequency | 50 Hz |
| Cooling Method | ONAN (Oil Natural Air Natural) |
| Primary Current (I1) | 1.75 A |
| Secondary Current (I2) | 139.1 A |
| Guaranteed No-Load Loss (P0) | 200 W |
| Guaranteed Load Loss (Pk at 75°C) | 1360 W |
| Short-Circuit Impedance (Uk) | 4.0% |
| HV Insulation Level | LI 75 / AC 35 (11kV Class) |
| Temperature Rise Limits | Top Oil ≤ 50K, Winding ≤ 55K (45°C Ambient) |
| Creepage Distance | ≥ 31 mm/kV (Outdoor Tropicalized Porcelain) |
| Core & Coil Weight | 310 kg |
| Insulating Oil Weight | 210 kg |
| Total Assembled Weight | 620 kg |
| Overall Footprint (L×W×H) | 1050 mm × 720 mm × 1250 mm |
| Governing Standards | IEC 60076, BS 171, SON NIS, NERC Code |
Technical Highlights
- This product combines dependable transformer platform design, flexible project configuration, and practical export-oriented construction. It is suitable for applications requiring stable electrical performance, configurable voltage ratios, outdoor durability, and documentation support for international project supply.
Application Scenarios
- Utility distribution networks
- Industrial plants and workshops
- Commercial buildings and mixed-use developments
- Public infrastructure projects
- Regional and municipal power distribution systems
Key Features
- 100 kVA rated capacity with optimized core design for energy-saving applications
- Three-phase oil-immersed structure for stable outdoor operating performance
- class configuration suitable for distribution and industrial feeder networks
- Low-loss design approach intended to reduce operating cost over service life
- Supports project-based winding, voltage ratio, and accessory customization
- Suitable for utility and industrial buyers prioritizing efficiency and life-cycle value
Optional Configurations
- Low-voltage side rating and voltage ratio
- Frequency: 50 Hz or 60 Hz
- Vector group and tapping range
- Copper or aluminum winding
- Cooling method, accessory package, and monitoring option
- Tank structure, coating system, and special environmental adaptation
- Color, nameplate language, and document package
- Ambient temperature, altitude, and installation condition adaptation
Frequently Asked Questions
What is the advantage of amorphous alloy cores?
Amorphous alloy cores have significantly lower no-load loss than conventional silicon steel, reducing energy consumption during the long periods when the transformer runs lightly loaded.
Are amorphous transformers suitable for utility distribution?
Yes. They are widely used on utility distribution networks where energy efficiency and total cost of ownership are primary selection criteria.
What standards apply to this transformer?
The unit is designed and tested to the applicable IEC or ANSI standards, with routine tests performed on every unit.
Can the transformer be customized for my network voltage?
Yes. Voltage ratio, tap range, vector group and impedance are configured to your network requirements.
What is the delivery lead time?
Standard delivery is 30 days after drawing approval, with the schedule confirmed against your final specification.