630 kVA 11kV Three-Phase On-Load Tap Changer (OLTC) Transformer

,

630 kVA 11kV Three-Phase On-Load Tap Changer (OLTC) Transformer

This 630 kva three-phase on-load tap changer (oltc) transformer is configured for a specific operating condition, application environment, or project requirement. It combines proven transformer platform design with targeted customization for winding material, environmental resistance, monitoring, voltage regulation, or special-duty performance according to export project needs.

Technical Parameters & Ratings

IEC / ANSI CertifiedFactory Standard
Rated Capacity630 kVA
Primary Voltage (U1)11,000 V (11 kV)
Secondary Voltage (U2)415 V / 240 V (3-Phase 4-Wire)
Vector GroupDyn11
Rated Frequency50 Hz
Cooling MethodONAN (Oil Natural Air Natural)
Primary Current (I1)11.02 A
Secondary Current (I2)876.5 A
Guaranteed No-Load Loss (P0)810 W
Guaranteed Load Loss (Pk at 75°C)5500 W
Short-Circuit Impedance (Uk)4.5%
HV Insulation LevelLI 75 / AC 35 (11kV Class)
Temperature Rise LimitsTop Oil ≤ 50K, Winding ≤ 55K (45°C Ambient)
Creepage Distance≥ 31 mm/kV (Outdoor Tropicalized Porcelain)
Core & Coil Weight1150 kg
Insulating Oil Weight710 kg
Total Assembled Weight2250 kg
Overall Footprint (L×W×H)1500 mm × 980 mm × 1620 mm
Governing StandardsIEC 60076, BS 171, SON NIS, NERC Code

Technical Highlights

  • This product combines dependable transformer platform design, flexible project configuration, and practical export-oriented construction. It is suitable for applications requiring stable electrical performance, configurable voltage ratios, outdoor durability, and documentation support for international project supply.

Application Scenarios

  • Utility distribution networks
  • Industrial plants and workshops
  • Commercial buildings and mixed-use developments
  • Public infrastructure projects
  • Regional and municipal power distribution systems

Key Features

  • Designed for electrical control, automation, and load-side switching functions
  • Configurable internal component arrangement according to process and feeder requirements
  • Supports communication, metering, and interface options for smart plant integration
  • Cabinet construction suitable for industrial and infrastructure environments
  • Project-oriented documentation, labeling, and wiring scheme support available
  • Suitable for export supply and customized control-package delivery

Optional Configurations

  • Low-voltage side rating and voltage ratio
  • Frequency: 50 Hz or 60 Hz
  • Vector group and tapping range
  • Copper or aluminum winding
  • Cooling method, accessory package, and monitoring option
  • Tank structure, coating system, and special environmental adaptation
  • Color, nameplate language, and document package
  • Ambient temperature, altitude, and installation condition adaptation

Frequently Asked Questions

What is the advantage of an OLTC over an off-circuit tap changer?

An on-load tap changer regulates voltage while the transformer remains energized, so voltage can be corrected without interrupting supply — essential for grids with fluctuating load or renewable infeed.

How many tap positions are normally provided?

Typical OLTC ranges are +/-8 x 1.25% or +/-9 steps, with the exact range set by your voltage regulation requirement and confirmed during design review.

Which tap changer brands are used?

OLTC units are supplied with proven on-load tap changers from established manufacturers. The final brand is agreed at order stage and stated on the nameplate and test reports.

Does the OLTC require periodic maintenance?

Yes. Diverter switch oil and contacts require periodic inspection per the tap changer manufacturer’s schedule; a maintenance recommendation is included in the document package.

Can this OLTC transformer be supplied as a mobile or pad-mounted unit?

It can be configured for station, pad-mounted or containerized layouts on request, subject to the cooling and tap changer access requirements of the final design.